INITIALIZATION 1. RESET MEMORY NOTICE:
HINT: The ECM memorizes the control conditions of the automatic transmission assembly and engine assembly. Therefore, when the automatic transmission assembly, valve body assembly or any of the shift solenoid valves has been replaced, it is necessary to reset the memory so that the ECM can memorize the new information. The reset procedure is as follows. (a) Connect the Techstream to the DLC3. (b) Turn the ignition switch to ON. (c) Turn the Techstream on. (d) Enter the following menus: Powertrain / Engine and ECT / Utility / Reset Memory. NOTICE: After performing Reset Memory, be sure to perform the Road Test (See page
HINT: The ECM learns through the Road Test. 2. ATF THERMAL DEGRADATION ESTIMATE RESET NOTICE: If either of the following conditions is met, perform ATF Thermal Degradation Estimate Reset.
(a) Connect the Techstream to the DLC3. (b) Turn the ignition switch to ON. NOTICE: Do not start the engine. (c) Turn the Techstream on. (d) Enter the following menus: Powertrain / Engine and ECT / Utility / ATF Thermal Degradation Estimate Reset. |
Toyota Tundra Service Manual > Sfi System: Evaporative Emission Control System Leak Detected (Gross Leak) (P0455,P0456)
DTC SUMMARY DTC No. Monitoring Item Malfunction Detection Condition Trouble Area Detection Timing Detection Logic P0455 EVAP gross leak Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. Reference pressure measured at start and at end of leak che ...