Toyota Tundra Service Manual: Inspection

INSPECTION

PROCEDURE

1. INSPECT COOLER (ROOM TEMPERATURE SENSOR) THERMISTOR

(a) Measure the resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

1 - 2

10°C (50°F)

3.00 to 3.73 kΩ

15°C (59°F)

2.45 to 2.88 kΩ

20°C (68°F)

1.95 to 2.30 kΩ

25°C (77°F)

1.60 to 1.80 kΩ

30°C (86°F)

1.28 to 1.47 kΩ

35°C (95°F)

1.00 to 1.22 kΩ

40°C (104°F)

0.80 to 1.00 kΩ

45°C (113°F)

0.65 to 0.85 kΩ

50°C (122°F)

0.50 to 0.70 kΩ

55°C (131°F)

0.44 to 0.60 kΩ

60°C (140°F)

0.36 to 0.50 kΩ

NOTICE:

  • Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.
  • When measuring the resistance, the sensor temperature must be the same as the ambient temperature.

HINT:

As the temperature increases, the resistance decreases (see the graph).

Text in Illustration

*a

Component without harness connected

(Cooler (Room Temperature Sensor) Thermistor)

*b

Resistance (kΩ)

*c

Temperature

If the result is not as specified, replace the cooler (room temperature sensor) thermistor.

    Components

    Installation

    See More:

    Toyota Tundra Service Manual > Thermostat: Inspection
    INSPECTION PROCEDURE 1. INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT HINT: The valve opening temperature is stamped on the water inlet with thermostat. (a) Immerse the water inlet with thermostat in water and gradually heat the water. (b) Check the valve opening temperature. Standard valve openi ...