INSPECTION PROCEDURE 1. INSPECT AIR SWITCHING VALVE ASSEMBLY
![]() (b) Check the operation of the air switching valve assembly. (1) Check that air does not flow from port A to port B. Text in Illustration
NOTICE: Make sure the applied pressure is 30 kPa (0.3 kgf/cm2, 4.4 psi) or less. If the result is not as specified, replace the air switching valve assembly. ![]() (2) Apply battery voltage across terminals 1 and 5. Text in Illustration
NOTICE: When applying voltage, do not touch terminals 2, 3 or 4. (3) Check that air flows from port A to port B. If the result is not as specified, replace the air switching valve assembly. |
Toyota Tundra Owners Manual > Multimedia: Setup
Setup menu You can adjust the multimedia system to your desired settings. Display "Setup" screen Press the "SETUP" button to display the "Setup" screen. Select to adjust the settings for operation sounds, screen animation, etc. Select to set the voice settings. Select to adjust the settings for cont ...