Toyota Tundra Service Manual: Installation

INSTALLATION

PROCEDURE

1. INSTALL STARTER ASSEMBLY

(a) Install the flywheel housing side cover.

(b) Install the starter with the 2 bolts.

Torque:

37 N·m {377 kgf·cm, 27 ft·lbf}

(c) Connect the starter wire with the nut.

Torque:

9.8 N·m {100 kgf·cm, 87 in·lbf}

(d) Connect the starter connector.

(e) Attach the 2 wire harness clamps.

2. INSTALL STARTER COVER

(a) Install the starter cover with the 3 bolts.

Torque:

12 N·m {117 kgf·cm, 8 ft·lbf}

3. INSTALL EXHAUST MANIFOLD SUB-ASSEMBLY RH

(See page )

4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Inspection

    Reassembly

    See More:

    Toyota Tundra Service Manual > Sfi System: Terminals Of Ecm
    TERMINALS OF ECM 1. CHECK ECM (a) Measure the voltage according to the value(s) in the table below. HINT: The standard voltage between each pair of ECM terminals is shown in the table below. The appropriate conditions for checking each pair of terminals are also indicated. The result of checks shoul ...