Toyota Tundra Service Manual: Installation

INSTALLATION

PROCEDURE

1. INSTALL STARTER ASSEMBLY

(a) Install the flywheel housing side cover.

(b) Install the starter with the 2 bolts.

Torque:

37 N·m {377 kgf·cm, 27 ft·lbf}

(c) Connect the starter wire with the nut.

Torque:

9.8 N·m {100 kgf·cm, 87 in·lbf}

(d) Connect the starter connector.

(e) Attach the 2 wire harness clamps.

2. INSTALL STARTER COVER

(a) Install the starter cover with the 3 bolts.

Torque:

12 N·m {117 kgf·cm, 8 ft·lbf}

3. INSTALL EXHAUST MANIFOLD SUB-ASSEMBLY RH

(See page )

4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Inspection

    Reassembly

    See More:

    Toyota Tundra Service Manual > Power Mirror Control System(w/ Memory): Power Mirrors do not Return to Memorized Position
    DESCRIPTION If any of the M1 or M2 seat memory switch is pressed, the outer mirror control ECU assembly LH detects the switch operation and sends the seat memory switch signal to the main body ECU (multiplex network body ECU) via CAN communication. The main body ECU (multiplex network body ECU) send ...