INSTALLATION PROCEDURE 1. INSTALL CANISTER PUMP MODULE
2. INSTALL CHARCOAL CANISTER ASSEMBLY (a) Install the charcoal canister assembly with the 4 bolts. Torque: 29 N·m {296 kgf·cm, 21 ft·lbf} (b) Attach the wire harness clamp. (c) Connect the vent line hose. (1) Push the vent line hose into the port and push the retainer to lock it. Text in Illustration
NOTICE:
(d) Connect the air inlet line hose. NOTICE:
(e) Connect the purge line hose and slide the clamp to secure the hose. (f) Connect the canister pump module connector. (g) Connect the wiring harness clamp bracket with the nut. Torque: 10 N·m {102 kgf·cm, 7 ft·lbf} |
Toyota Tundra Service Manual > Shift Lever Assembly(for Floor Shift Type): Disassembly
DISASSEMBLY PROCEDURE 1. REMOVE SHIFT LEVER CAP (a) Using a screwdriver, detach the 2 claws and remove the shift lever cap from the upper position indicator housing. Text in Illustration *a Protective Tape NOTICE: Be careful not to damage the shift lever cap. HINT: Tape the screwdriver tip before us ...