INSPECTION PROCEDURE 1. INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT ![]() HINT: The valve opening temperature is stamped on the water inlet with thermostat.
(b) Check the valve opening temperature. Standard valve opening temperature: 80 to 84°C (176 to 183°F) If the valve opening temperature is not within the specified range, replace the water inlet sub-assembly with thermostat.
(d) Check that the valve is fully closed when the water inlet with thermostat is at a low temperature (below 77°C (171°F)). If it is not fully closed, replace the water inlet sub-assembly with thermostat. |
Toyota Tundra Service Manual > Sfi System: A/F Sensor Slow Response - Rich to Lean Bank 1 Sensor 1 (P014C-P014F,P015A-P015D)
DESCRIPTION HINT: Refer to DTC P2195 (See page ). DTC No. DTC Detection Condition Trouble Area P014C The "Rich to Lean response rate deterioration level*" value is less than the standard. (2 trip detection logic) Air fuel ratio sensor (for bank 1 sensor 1) Air fuel ratio sensor (for bank 1 sensor 1) ...