INSPECTION PROCEDURE 1. INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT HINT: The valve opening temperature is stamped on the water inlet with thermostat.
(b) Check the valve opening temperature. Standard valve opening temperature: 80 to 84°C (176 to 183°F) If the valve opening temperature is not within the specified range, replace the water inlet sub-assembly with thermostat.
(d) Check that the valve is fully closed when the water inlet with thermostat is at a low temperature (below 77°C (171°F)). If it is not fully closed, replace the water inlet sub-assembly with thermostat. |
Toyota Tundra Service Manual > Instrument Panel Safety Pad(for Column Shift Type): Removal
REMOVAL PROCEDURE 1. TABLE OF BOLT, SCREW AND NUT HINT: All bolts, screws and nuts relevant to installing and removing the instrument panel are shown along with their alphabet code below. 2. PRECAUTION NOTICE: After turning the ignition switch off, waiting time may be required before disconnecting t ...