DESCRIPTION Refer to DTC P0894 (See page
). |
DTC Code | DTC Detection Condition |
Trouble Area | | P2716 |
Open or short is detected in the shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic). |
- Open or short in shift solenoid valve SLT circuit
- Shift solenoid valve SLT
- ECM
| MONITOR DESCRIPTION
When
an open or short in the shift solenoid valve SLT circuit is detected,
the ECM interprets this as a fault. The ECM will turn on the MIL and
store the DTC. MONITOR STRATEGY |
Related DTCs | P2716: Shift solenoid valve SLT/Range check | |
Required sensors/Components | Shift solenoid valve SLT | |
Frequency of operation | Continuous | |
Duration | 1 second | |
MIL operation | Immediately | |
Sequence of operation | None | TYPICAL ENABLING CONDITIONS |
The monitor will run whenever the following DTCs are not present |
None | | Solenoid current cut status |
Not cut | | Battery voltage |
11 V or more | | Ignition switch |
ON | | Starter |
OFF | TYPICAL MALFUNCTION THRESHOLDS |
Solenoid voltage monitor signal from solenoid driver MIC |
No signal | COMPONENT OPERATING RANGE |
Output signal duty | Less than 100% | WIRING DIAGRAM
CAUTION / NOTICE / HINT
NOTICE: Perform the universal trip to clear permanent DTCs (See page
). PROCEDURE
| 1. |
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT) |
| (a) Disconnect the D83 transmission wire connector. | |
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance: |
Tester Connection | Condition |
Specified Condition | |
18 (SLT+) - 7 (SLT-) |
20°C (68°F) | 5.0 to 5.6 Ω | |
18 (SLT+) - Body ground |
Always | 10 kΩ or higher | |
7 (SLT-) - Body ground |
Always | 10 kΩ or higher | Text in Illustration |
*a | Component without harness connected
(Transmission Wire) |
| NG |
| GO TO STEP 3 |
|
OK |
| |
| 2. |
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
| (a) Disconnect the D74 ECM connector. | |
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance: |
Tester Connection | Condition |
Specified Condition | |
D74-9 (SLT+) - D74-8 (SLT-) |
20°C (68°F) | 5.0 to 5.6 Ω | |
D74-9 (SLT+) - Body ground |
Always | 10 kΩ or higher | |
D74-8 (SLT-) - Body ground |
Always | 10 kΩ or higher | Text in Illustration |
*a | Front view of wire harness connector
(to ECM) |
| OK |
| REPLACE ECM |
| NG |
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
| 3. |
INSPECT SHIFT SOLENOID VALVE SLT |
| OK |
| REPAIR OR REPLACE TRANSMISSION WIRE |
| NG |
| REPLACE SHIFT SOLENOID VALVE SLT | |