Toyota Tundra Service Manual: Installation

INSTALLATION

PROCEDURE

1. INSTALL WATER PUMP ASSEMBLY

(a) Install a new gasket and the water pump assembly with the 8 bolts shown in the illustration.

Torque:

for bolt A :

47 N·m {479 kgf·cm, 35 ft·lbf}

for bolt B :

23 N·m {235 kgf·cm, 17 ft·lbf}

for bolt C :

20 N·m {204 kgf·cm, 15 ft·lbf}

2. INSTALL WATER PUMP PULLEY

(a) Temporarily install the water pump pulley with the 4 bolts.

(b) Using SST, hold the water pump pulley and tighten the 4 bolts.

SST: 09960-10010

09962-01000

09963-01000

Torque:

21 N·m {214 kgf·cm, 15 ft·lbf}

3. INSTALL WATER INLET HOUSING

(a) Install a new gasket to the water pump assembly.

(b) Install the water inlet housing with the 3 bolts.

Torque:

21 N·m {214 kgf·cm, 15 ft·lbf}

4. CONNECT NO. 5 WATER BY-PASS HOSE

(a) Connect the No. 5 water by-pass hose.

HINT:

The direction of hose clamp is indicated in the illustration.

5. CONNECT NO. 8 WATER BY-PASS HOSE

(a) Connect the No. 8 water by-pass hose.

HINT:

The direction of hose clamp is indicated in the illustration.

6. INSTALL NO. 1 WATER BY-PASS HOSE

(a) Install the No. 1 water by-pass hose.

HINT:

The direction of hose clamp is indicated in the illustration.

7. INSTALL WATER INLET SUB-ASSEMBLY WITH THERMOSTAT

(See page )

8. INSTALL FAN SHROUD

(See page )

    Components

    On-vehicle Inspection

    See More:

    Toyota Tundra Service Manual > Sfi System: Evaporative Emission Control System Incorrect Purge Flow (P0441)
    DTC SUMMARY DTC No. Monitoring Item Malfunction Detection Condition Trouble Area Detection Timing Detection Logic P0441 Purge VSV (Vacuum Switching Valve) stuck open Leak detection pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. Reference pressure measured a ...