INSTALLATION PROCEDURE 1. INSTALL CANISTER PUMP MODULE
2. INSTALL CHARCOAL CANISTER ASSEMBLY (a) Install the charcoal canister assembly with the 4 bolts. Torque: 29 N·m {296 kgf·cm, 21 ft·lbf} (b) Attach the wire harness clamp. (c) Connect the vent line hose. (1) Push the vent line hose into the port and push the retainer to lock it. Text in Illustration
NOTICE:
(d) Connect the air inlet line hose. NOTICE:
(e) Connect the purge line hose and slide the clamp to secure the hose. (f) Connect the canister pump module connector. (g) Connect the wiring harness clamp bracket with the nut. Torque: 10 N·m {102 kgf·cm, 7 ft·lbf} |
Toyota Tundra Service Manual > Lighting System: IG Signal Circuit
DESCRIPTION This circuit detects the ignition switch ON or off condition, and sends it to the main body ECU (multiplex network body ECU). WIRING DIAGRAM CAUTION / NOTICE / HINT NOTICE: Inspect the fuses for circuits related to this system before performing the following procedure. PROCEDURE 1. READ ...