INSTALLATION PROCEDURE 1. INSTALL CANISTER PUMP MODULE
2. INSTALL CHARCOAL CANISTER ASSEMBLY (a) Install the charcoal canister assembly with the 4 bolts. Torque: 29 N·m {296 kgf·cm, 21 ft·lbf} (b) Attach the wire harness clamp. (c) Connect the vent line hose. (1) Push the vent line hose into the port and push the retainer to lock it. Text in Illustration
NOTICE:
(d) Connect the air inlet line hose. NOTICE:
(e) Connect the purge line hose and slide the clamp to secure the hose. (f) Connect the canister pump module connector. (g) Connect the wiring harness clamp bracket with the nut. Torque: 10 N·m {102 kgf·cm, 7 ft·lbf} |
Toyota Tundra Service Manual > Touch Select 2-4 And High-low System: Automatic Disconnecting Differential Motor Limit Switch Circuit (P17A4)
DESCRIPTION When the A.D.D. actuator is switching between 2WD and 4WD, the DL1 and DL2 terminals of the limit switch are in one of the ON/OFF combinations listed in the table below. Terminal In 2WD Switching between 2WD and 4WD In 4WD DL1 OFF (OPEN) ON (GND) ON (GND) DL2 ON (GND) ON (GND) OFF (OPEN) ...