| DESCRIPTION When the volume of washer fluid decreases below a certain level (when the washer 
fluid level warning switch is turned ON), the combination meter warns the driver 
through the warning message on the combination meter. WIRING DIAGRAM   PROCEDURE 
	
		| 1.  | READ VALUE USING TECHSTREAM (WASHER FLUID LEVEL WARNING SWITCH) |  (a) Check the Data List for proper functioning of the washer fluid level warning 
switch.Combination Meter 
	
		| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |  
		| Washer Switch | Washer fluid level warning switch / ON or OFF | ON: Washer jar is empty OFF: Washer jar is full | - |  OK:  On screen, each item changes between ON and OFF according to above chart. 
	
		| OK |   | PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
		 |  
	
		| 
			
				| NG |  
				|   |  |  
	
		| 2.  | CHECK WASHER FLUID LEVEL WARNING SWITCH ASSEMBLY |  
	
		| (a) Disconnect the A27 switch connector. |  |  (b) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
	
		| Tester Connection | Condition | Specified Condition |  
		| A27-1 (S) - A27-2 (E) | Washer jar is empty | Below 5.5 Ω |  
		| A27-1 (S) - A27-2 (E) | Washer jar is full | 10 kΩ or higher |  
	
		| NG |   | REPLACE WASHER FLUID LEVEL WARNING SWITCH ASSEMBLY |  
	
		| 
			
				| OK |  
				|   |  |  
	
		| 3.  | CHECK HARNESS AND CONNECTOR (WASHER FLUID LEVEL WARNING SWITCH - COMBINATION 
		METER) |  
	
		| (a) Disconnect the A27 switch connector. |  |  (b) Disconnect the J28 meter connector. (c) Measure the resistance according to the value(s) in the table below. Standard Resistance:  
	
		| Tester Connection | Condition | Specified Condition |  
		| A27-1 (S) - J28-15 (WLVL) | Always | Below 1 Ω |  
		| A27-2 (E) - Body ground | Always | Below 1 Ω |  
		| A27-1 (S) - Body ground | Always | 10 kΩ or higher |  
	
		| OK |   | REPLACE COMBINATION METER ASSEMBLY  |  
	
		| NG |   | REPAIR OR REPLACE HARNESS OR CONNECTOR |  |