DESCRIPTION This DTC is stored when a beam axis inspection has not been performed for the blind spot monitor sensor RH. HINT: This DTC is always stored after replacing a blind spot monitor sensor. The purpose of this DTC is to ensure that beam axis inspection is performed. Completing the beam axis inspection after replacing a blind spot monitor sensor prevents this DTC from being output.
PROCEDURE
(a) Change the blind spot monitor sensor RH to Test Mode using the Techstream. HINT: Refer to Blind Spot Monitor Beam Axis Inspection (See page
|
Toyota Tundra Service Manual > Lighting System: Interior Light Circuit
DESCRIPTION The main body ECU (multiplex network body ECU) controls the operation of the following lights: Roof console box (front interior light) No. 1 room light assembly (rear interior light) Foot light bulb (w/ Foot Light) Transponder key coil (w/ Ignition Key Cylinder Light) WIRING DIAGRAM CAUT ...