INSPECTION PROCEDURE 1. INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT ![]() HINT: The valve opening temperature is stamped on the water inlet with thermostat.
(b) Check the valve opening temperature. Standard valve opening temperature: 80 to 84°C (176 to 183°F) If the valve opening temperature is not within the specified range, replace the water inlet sub-assembly with thermostat.
(d) Check that the valve is fully closed when the water inlet with thermostat is at a low temperature (below 77°C (171°F)). If it is not fully closed, replace the water inlet sub-assembly with thermostat. |
Toyota Tundra Service Manual > Lighting: License Plate Light Assembly
Components COMPONENTS ILLUSTRATION Disassembly DISASSEMBLY CAUTION / NOTICE / HINT HINT: Use the same procedure for the RH and LH sides. The procedure listed below is for the LH side. PROCEDURE 1. REMOVE LICENSE PLATE LIGHT BULB (a) Turn the license plate light bulb socket with the license plate lig ...