Toyota Tundra Service Manual: Inspection

INSPECTION

PROCEDURE

1. INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT

HINT:

The valve opening temperature is stamped on the water inlet with thermostat.

(a) Immerse the water inlet with thermostat in water and gradually heat the water.

(b) Check the valve opening temperature.

Standard valve opening temperature:

80 to 84°C (176 to 183°F)

If the valve opening temperature is not within the specified range, replace the water inlet sub-assembly with thermostat.

(c) Check the valve lift.

Standard valve lift:

10 mm (0.394 in.) or more at 95°C (203°F)

If the valve lift is not as specified, replace the water inlet sub-assembly with thermostat.

(d) Check that the valve is fully closed when the water inlet with thermostat is at a low temperature (below 77°C (171°F)).

If it is not fully closed, replace the water inlet sub-assembly with thermostat.

    Components

    Installation

    See More:

    Toyota Tundra Service Manual > Millimeter Wave Radar Sensor: Adjustment
    ADJUSTMENT CAUTION / NOTICE / HINT CAUTION: Radiofrequency radiation exposure information: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be kept with minimum distance of 20 cm (7.87 in.) between the radiator (antenna) and ...

    Toyota Tundra Owners Manual

    Toyota Tundra Service Manual

    © 2025 Copyright www.ttundra.com
    0.0096