INSPECTION PROCEDURE 1. INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT ![]() HINT: The valve opening temperature is stamped on the water inlet with thermostat.
(b) Check the valve opening temperature. Standard valve opening temperature: 80 to 84°C (176 to 183°F) If the valve opening temperature is not within the specified range, replace the water inlet sub-assembly with thermostat.
(d) Check that the valve is fully closed when the water inlet with thermostat is at a low temperature (below 77°C (171°F)). If it is not fully closed, replace the water inlet sub-assembly with thermostat. |
Toyota Tundra Service Manual > Power Window Control System(w/o Jam Protection Function): Terminals Of Ecu
TERMINALS OF ECU 1. CHECK POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (a) Disconnect the N2 master switch connector. (b) Measure the resistance and voltage according to the value(s) in the table below. for Double Cab: Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Cond ...