INSPECTION PROCEDURE 1. INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT ![]() HINT: The valve opening temperature is stamped on the water inlet with thermostat.
(b) Check the valve opening temperature. Standard valve opening temperature: 80 to 84°C (176 to 183°F) If the valve opening temperature is not within the specified range, replace the water inlet sub-assembly with thermostat.
(d) Check that the valve is fully closed when the water inlet with thermostat is at a low temperature (below 77°C (171°F)). If it is not fully closed, replace the water inlet sub-assembly with thermostat. |
Toyota Tundra Service Manual > Vane Pump(for 3ur-fe, 3ur-fbe): Removal
REMOVAL PROCEDURE 1. PRECAUTION NOTICE: After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (See page ). 2. ...