INSPECTION PROCEDURE 1. INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT ![]() HINT: The valve opening temperature is stamped on the water inlet with thermostat.
(b) Check the valve opening temperature. Standard valve opening temperature: 80 to 84°C (176 to 183°F) If the valve opening temperature is not within the specified range, replace the water inlet sub-assembly with thermostat.
(d) Check that the valve is fully closed when the water inlet with thermostat is at a low temperature (below 77°C (171°F)). If it is not fully closed, replace the water inlet sub-assembly with thermostat. |
Toyota Tundra Service Manual > Millimeter Wave Radar Sensor: Adjustment
ADJUSTMENT CAUTION / NOTICE / HINT CAUTION: Radiofrequency radiation exposure information: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be kept with minimum distance of 20 cm (7.87 in.) between the radiator (antenna) and ...