INSPECTION PROCEDURE 1. INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT ![]() HINT: The valve opening temperature is stamped on the water inlet with thermostat.
(b) Check the valve opening temperature. Standard valve opening temperature: 80 to 84°C (176 to 183°F) If the valve opening temperature is not within the specified range, replace the water inlet sub-assembly with thermostat.
(d) Check that the valve is fully closed when the water inlet with thermostat is at a low temperature (below 77°C (171°F)). If it is not fully closed, replace the water inlet sub-assembly with thermostat. |
Toyota Tundra Service Manual > Power Window Control System(w/o Jam Protection Function): Remote Up / Down Function does not Operate
DESCRIPTION With the ignition switch ON, the master switch transmits remote switch signals to the regulator switches of the front passenger door power window and rear door power windows. Then, each power window regulator switch drives its respective power window regulator motor. HINT: The front pass ...