INSPECTION PROCEDURE 1. INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT HINT: The valve opening temperature is stamped on the water inlet with thermostat.
(b) Check the valve opening temperature. Standard valve opening temperature: 80 to 84°C (176 to 183°F) If the valve opening temperature is not within the specified range, replace the water inlet sub-assembly with thermostat.
(d) Check that the valve is fully closed when the water inlet with thermostat is at a low temperature (below 77°C (171°F)). If it is not fully closed, replace the water inlet sub-assembly with thermostat. |
Toyota Tundra Service Manual > Sfi System: Oxygen Sensor Heater Control Circuit Low (Bank 1 Sensor 2) (P0037,P0038,P0057,P0058,P0141,P0161,P102D,P105D)
DESCRIPTION Refer to DTC P0136 (See page ). HINT: When any of these DTCs are stored, the ECM enters fail-safe mode. The ECM turns off the Heated Oxygen (HO2) sensor heater in fail-safe mode. Fail-safe mode continues until the ignition switch is turned off. The ECM provides a pulse width modulated co ...