Toyota Tundra Service Manual: On-vehicle Inspection

ON-VEHICLE INSPECTION

PROCEDURE

1. CHECK HEATED OXYGEN SENSOR

(a) Disconnect the heated oxygen sensor connector.

(b) Measure the heater resistance according to the value(s) in the table below.

Standard Resistance:

Tester Connection

Condition

Specified Condition

1 (HT1B) - 2 (+B)

(for Bank 1)

20°C (68°F)

11 to 16 Ω

1 (HT2B) - 2 (+B)

(for Bank 2)

If the result is not as specified, replace the heated oxygen sensor.

(c) Connect the heated oxygen sensor connector.

    Installation

    Removal

    See More:

    Toyota Tundra Service Manual > Sfi System: Evaporative Emission Pressure Switching Valve Stuck OFF (P2420)
    DTC SUMMARY DTC No. Monitoring Item Malfunction Detection Condition Trouble Area Detection Timing Detection Logic P2420 Vent valve stuck open (vent) Following condition met during key-off EVAP monitor: EVAP pressure change when vent valve closed (ON) less than 0.3 kPa-g (2.25 mmHg-g) Canister pump m ...